For a
printable version, please see the PDF
of this data sheet.
Easy as 1-2-3:
1.
Test continuity
2.
Test integrity
3.
Accept or reject cable
The continuity test and twisted pair
integrity test can be performed on a SCSI cable in about 10 seconds.
Prevent Costly Downtime
When a SCSI-configured system has a cable
problem the symptoms vary greatly, from intermittent operation to SCSI "hangup,"
resulting in excessive system installation delays and costs.
The SCSI Cable Tester is designed with
emphasis on simplicity of use. New users will be able to operate the tester
within five minutes.
With today's increased SCSI data rates,
cabling becomes an even more critical issue.
Description
of Tests
Continuity Test:
A.
Tests pin to pin connection of cable.
B.
Checks for opens.
C.
Checks for wire to wire shorts.
D.
Checks for wire to shielding shorts.
Integrity Test:
Tests for twisted
pairing. By measuring the capacitive reactance of a signal pair, the integrity
test will determine if each signal pair in the cable has proper capacitive
reactance. A green LED is associated with each pair of signal lines. If the
capacitive reactance of a pair falls within the acceptable reference range, the
green LED will light. Should ANY signal pair not pass the test the red Integrity
Error LED will illuminate.
SCSI Cables Tested:
50-pin
Centronic type cables (alt. 2 - A cable)
50-pin
Hi-Density (alt. 1 - A cable)
68-pin
Hi-Density (P cable)
Conversion cables:
50-pin
Centronic type to 50-pin Hi-Density
50-pin
Centronic type to 68-pin Hi-Density
50-pin
Hi-Density to 68-pin Hi-Density
Maximum number of pins:
68
Maximum cable length:
200 feet
Easy
Continuity Testing
Follow the instructions on
the front panel:
CONTINUITY TEST
1. SELECT CABLE OPTION
SWITCHES (PIN COUNT, CABLE TYPE, CABLE LENGTH).
2. CONNECT BOTH ENDS OF CABLE TO CONTINUITY TESTER.
3. PRESS RESET. IF CONTINUITY ERROR LED (RED) IS "ON," THE CABLE IS
BAD.
GREEN LEDS "ON" INDICATE VALID PIN TO PIN
CONTINUITY.
4. REMOVE CABLE (BOTH ENDS) FROM CONTINUITY TESTER.
And read the test results on the Continuity
display:
(Darkened indicator for pin no. 38 shows
Continuity Test failure)
Easy Integrity Testing
Follow the instructions on
the front panel:
INTEGRITY TEST
5. CONNECT ONLY ONE END
OF CABLE TO INTEGRITY TESTER.
6. PRESS RESET. IF INTEGRITY ERROR LED (RED) IS "ON," THE CABLE IS
BAD.
GREEN LEDS "ON" INDICATE VALID PIN PAIR
INTEGRITY.
7. REMOVE CONNECTOR FROM TESTER.
8. CONNECT OTHER END OF CABLE TO INTEGRITY TESTER AND REPEAT STEP 6.
And read the test results on the Integrity
display:
(Darkened indicator for twisted pair no. 13
shows Integrity Test failure)
Specifications
ST123 SCSI Cable Tester
Safety approvals
UL, CSA, TUV, CE
EMI/RFI
FCC Class A, CE
Test Conditions
Continuity Test: TTL level signals
Integrity Test: 5 V maximum;
current in picoamp range
Environmental
Relative humidity:
0-95% non-condensing
Operating temperature: 0-50°C
Power
Requirements
Voltage: 115/220 V ac, auto select
Frequency: 50-60 Hz, 32 Watts
Weight
10 lbs
Physical Size
Height: 4.3 in. (109 mm)
Width: 17 in. (432 mm)
Depth: 11.5 in. (292 mm)
Warranty Two
Year Limited Warranty
- Specifications subject to change without notice -
See ST-1000
for hand held testing
and
Comparison between cable testers.
|